23A Super Alkaline Battery
A 23A 12V Super Alkaline Battery The EPS general series VRLA battery with optimum design offers you 5 years full maintenance free design life. This battery with its improved reliability is highly ..
- Brands GSS Group
- Product Code: EPS23A
- Availability: 7-10 Days
Tags: EPS, super alkaline, battery
A 23A 12V Super Alkaline Battery
The EPS general series VRLA battery with optimum design offers you 5 years full maintenance free design life.
This battery with its improved reliability is highly suited for security and alarm systems, UPS systems, emergency light systems and other small backup applications.
Maintenance & Cautions:
- Do NOT overcharge or discharge the battery
- Always charge batteries with the correct voltage
- Recharge capacity is 1.1 - 1.15 times the discharge capacity
- Effect of temperature on cycle charge voltage: -5mV/degrees per cell
- Temperature, recharge rate and the depth of discharge affect battery life
- Battery MUST always be kept in an upright position
Battery Weight & Capacity | |
Battery Capacity | 52mAh (Test conditions: RH60 ± 15%, 20 ± 2 °C , 20K Ω, 24h/d, end voltage:6V) |
Battery Weight | Approximate 7.7g |
Chemical Systems, Voltages & Designation | |
Chemical Systems | (-) Zn—KOH—MnO2(+) 0%Hg |
Designation | 23A、L1028、A23、MN21、MS21、V23GA、LR23A |
Nominal Voltage | 12V |
Dimensions | |
A | 9.9-10.5mm |
B | 27.5-28.5m |
Heavy Metal Content | |
Cadmium | max 5ppm |
Mercury | max 1ppm |
Leakage Resistance | |
Condition | RH60 ± 15%, 20 ± 2 °C , 20KΩ, 24h/d,end voltage:4.8V |
Project | Leakage Resistance when over-discharge. |
Result | No visible leakage or explosion. |
Standard | N=9 AC=0 R=1 |
Life Expectancy | |
Expiry Date | 1 Year |
Open & Closed Circuit Voltage Load resistance 400Ω, 0.3S | |
/ | OCV(V) |
Initial | ≥12.0 |
Reference Documents | |
IEC 60086-1 | 2000 - Primary Batteries – General |
IEC 60086-2 | 2001 - Primary Batteries - Specification Sheets |
Service Output | |
*Note | The initial discharge test shall commence within 30 days of manufacture. During the stored period the cells shall be stored in room temperature conditions |
End Voltage | 6.0V |
Initial | 95h(MAD) |
Load | 20KΩ |
Test Mode | 24h/d |
Electrical Characteristics | |
Testing Accuracy | All samples are normalized for 8 hours at least, in the above environment prior to measurement. The digital voltmeter (DCM) has a precision rating of 1mV (internal resistance not less than 1 Megohm). The load resistance of the total circuit is accurate within ±0.5% of the specified value. |
Testing Environment | Unless otherwise stated, all measurements are to be performed at a Standard Environment of 20 ± 2°C / 60 ± 15% RH |