12VDC 5A Metal Enclosure & Keylock PSU

An 12VDC 5A Powersupply in Metal Enclosure with Keylock. A 60w constant voltage uninterruptible power supply that meets the RoHS requirements.    ..

  • Brands GSS Group
  • Product Code: ZTP1205B
  • Availability: 2-3 Days

Tags: 5a, Powersupply, metal enclosure, keylock

An 12VDC 5A Powersupply in Metal Enclosure with Keylock.

A 60w constant voltage uninterruptible power supply that meets the RoHS requirements.

 

 

Battery Specification
Battery Discharge Over Current Protection When battery supply power alone, the discharge current exceeds 5-6A, it will cut off.
Battery Low Voltage Protection The product will cut off when battery voltage descends to10V+/-0.5V by battery power alone.
Battery Reverse Connect Protection The battery will not charge and discharge when the battery cables are reversed.
Certifications
EMI Standards EN 55022:2010
Dielectric Strength (Hi-pot)
Primary - Earth 1500Vac 5mAMax / 60second (0 second for production)
Primary - Secondary 3000Vac 5mAMax / 60second (3 second for production)
Secondary - Earth 1500Vac 5mAMax / 60second (0 second for production)
EMS Standards
EN 61000-3-2 Harmonic current emissions, class c.
EN 61000-3-3 Voltage fluctuations & flicker
EN 61000-4-2 Electrostatic Discharge (ESD)
EN 61000-4-3 Radio-Frequency Continuous radiated disturbance
EN 61000-4-5 Surge Immunity Test
EN 61000-4-6 Radio-Frequency Continuous conducted disturbance
EN 61000-4-8 Power Frequency Magnetic Field Test
Environmental Characteristics
Burn-In The power supply shall be in burn-in test at least 4 hours with full load condition in 40℃ environment.
Operating Humidity 10%RH - 90%RH
Operating Temperature 25℃ - +40℃
Storage Humidity 5% - 60%RH
Storage Temperature -40℃ - +80℃
Vibration 10 - 300Hz sweep at a constant acceleration of 1.0G (Breadth: 3.5mm) for 1Hour for each of the perpendicular axes X, Y, Z.
Waterproof Grade None
Electrical Characteristics
Charge Current When the battery voltage is lower than the output voltage, the battery will be charged and maximum charging current is 1.5A.
Discharge Current When the AC input suddenly cuts off, it will convert to battery power, the maximum supply current is 5A
Efficiency 80% min. @ input 110Vac& Full load; 84% min. @ input 220Vac& Full load.
Fall Time 50mS max. @ FULL load.
Grounded Resistance < 0.1Ω,25A, 1Minute
Hold Up Time 60mS min. @ Full load &110Vac/60Hz input turn off at worst case 60mS min. @ Full load &220Vac/50Hz input turn off at worst case
Input AC Current 1.5Amax. @ input 100-240Vac & Full load.
Input Frequency Minimum - 47Hz Nominal - 60Hz/50Hz Maximum - 63Hz
Input Voltage Minimum - 90Vac Nominal - 100-240Vac Maximum - 264Vac
Inrush Current 30Amax. @ input 240Vac
Insulation Resistance 50MΩ min. at primary - secondary add 500Vdc test voltage.
Leakage Current 0.75mAmax. @ input 240Vac/50Hz
Load Adjustment Rate +/-2%
Max. Load 5A
Min. Load 0.0A
MTBF The MTBF shall be at least 30,000hours at 25℃ in full load and nominal input condition.
Output 13.8VDC
Output Adjustable potentiometer Output voltage is adjustable by potentiometer, output voltage range between DC12-14V.
Output voltage Overshoot / Undershoot 10% max. When the power on / off
Output voltage Range 12-14VDC
Overcurrent Protection The product will hiccup in protection mode when the output is over 110% - 150% full load, and shall enter self-recovery when the overcurrent is removed
Power Consumption 0.6Min. @ input 110AC & Full load. 0.5Min. @ input 220AC & Full load.
R + N 100mVp-p
Ripple & Noise Measurement is done at 20MHz bandwidth oscilloscope and the output parallels a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor. (Test under the condition of rated input and rated output)
Rise Time 50mS max. @ FULL load
Short Circuit Protection The products will hiccup in protection mode when the output short circuits, and will enter self-recovery when the short circuit condition is removed.
Turn - On Delay Time 3.0S max. @ input 100 - 240 Vac & Full load
Physical Characteristics
AC Input With AC input, red light on. Without AC input, red light off
AC Input Connection AC input connect L,N & GND
AC Input Switch AC input is connected when switch is in ON position and AC input is cut off in OFF position
Battery Charge With AC input and no connection to battery, yellow light on. When connecting to battery and charging, yellow light blinks. When AC cuts off and battery discharges, yellow light on.
Battery Connection Battery connect battery+ & battery-
Battery Trigger Switch When connecting to battery without AC input, please press the white switch to trigger the battery discharge
DC Output With DC output, green light on. Without DC output, green light off
DC Output Connection DC output connect output+ & output-
Low Battery Alarm In battery discharge, red light is on when voltage is lower than 11±0.4V.